Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/10846
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_MechanicalBehaviorSilver.PDF765,97 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorLevy Neto, Flaminio-
dc.contributor.authorBrito, Luciana de Moura-
dc.contributor.authorElias, Antônio Carlos-
dc.date.accessioned2012-06-28T13:18:35Z-
dc.date.available2012-06-28T13:18:35Z-
dc.date.issued2004-04-
dc.identifier.citationLEVY NETO, Flaminio; BRITO, Luciana de Moura; ELIAS, Antônio Carlos. Mechanical behavior of silver alloys used as cast post and core in maxillary incisors. Materials Research, São Carlos, v. 7, n. 2, p. 255-262, abr./jun. 2004. Disponível em:<http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200007&lng=pt&nrm=iso&tlng=en>. Acesso em: 21 jun. 2012.en
dc.identifier.urihttp://repositorio.unb.br/handle/10482/10846-
dc.language.isoInglêsen
dc.publisherABM, ABC, ABPolen
dc.rightsAcesso Abertoen
dc.titleMechanical behavior of silver alloys used as cast post and core in maxillary incisorsen
dc.typeArtigoen
dc.subject.keywordLigas (Metalurgia) - prataen
dc.subject.keywordMecânica - dinâmicaen
dc.subject.keywordIncisivos (Dentes)en
dc.rights.licenseMaterials Research - Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons(Attribution-NonCommercial 3.0 Unported (CC BY-NC 3.0) ). Fonte: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392004000200007&lng=pt&nrm=iso&tlng=en. Acesso em: 21 jun. 2012.en
dc.identifier.doihttp://dx.doi.org/10.1590/S1516-14392004000200007en
dc.description.abstract1This experimental "in vitro" investigation is mainly concerned with the mechanical behavior of twenty plastic analogous simulating endodonticaly treated maxillary central incisor roots, divided in two groups, which were restored with: (i) silver (10 specimens, Ag - 80%); and (ii) silver – palladium (10 specimens, Ag – 58.5% / Pd – 27.4%) cast alloys. All the restored analogous were clamped inside stainless steel cylinders filled with acrylic resin, and were tested to failure in an INSTRON machine. The static compressive loads were applied with an inclination of 45° relatively to the longitudinal direction of the teeth. On average, the specimens restored with Ag– Pd presented higher values of final failure load (i.e. fracture or excessive plastic bending) and stiffness. On the other hand, those restored with Ag presented average proportional limit loads which were, in comparison, about 5% higher.-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Este item está licenciada sob uma Licença Creative Commons Creative Commons