Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/14178
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_UseDiagnodentDiagnosis.pdf72,62 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCosta, Ana Maria-
dc.contributor.authorPaula, Lilian Marly de-
dc.contributor.authorBezerra, Ana Cristina Barreto-
dc.date.accessioned2013-09-23T21:05:53Z-
dc.date.available2013-09-23T21:05:53Z-
dc.date.issued2008-01-
dc.identifier.citationCOSTA, Ana Maria; PAULA, Lilian Marly de; BEZERRA, Ana Cristina Barreto. Use of diagnodent® for diagnosis of non-cavitated occlusal dentin caries. Journal of Applied Oral Science, Bauru, v. 16, n. 1, jan./fev. 2008. Disponível em: <http://www.scielo.br/scielo.php?script=sci_abstract&pid=S1678-77572008000100005&lng=en&nrm=iso&tlng=en>. Acesso em: 20 set. 2013. DOI: http://dx.doi.org/10.1590/S1678-77572008000100005.en
dc.identifier.urihttp://repositorio.unb.br/handle/10482/14178-
dc.description.abstractThe purpose of this study was to evaluate the use of a laser fluorescence device for detection of occlusal caries in permanent teeth. One hundred and ninety-nine non-cavitated teeth from 26 patients aged 10 to 13 years were selected. After dental prophylaxis, two previously calibrated dentists examined the teeth. Visual inspection, radiographic examination and laser measurements were performed under standardized conditions. The validation method was cavity preparation with a small cone-shaped diamond bur, when the two examiners agreed about the presence of dentin caries. It was found that the laser detection method produced high values of sensitivity (0.93) and specificity (0.75) and a moderate positive predictive value (0.63). The laser device showed the lowest value of likelihood ratio (3.68). Kappa coefficient showed good repeatability for all methods. Although the laser device had an acceptable performance, this equipment should be used as an adjunct method to visual inspection to avoid false positive results.en
dc.language.isoInglêsen
dc.publisherFaculdade de Odontologia de Bauru - USPen
dc.rightsAcesso Abertoen
dc.titleUse of diagnodent® for diagnosis of non-cavitated occlusal dentin cariesen
dc.typeArtigoen
dc.subject.keywordCáries dentáriasen
dc.subject.keywordCáries dentárias em criançasen
dc.subject.keywordDentes - doençasen
dc.subject.keywordCáries dentárias - prevençãoen
dc.subject.keywordLasers em odontologiaen
dc.rights.licenseJournal of Applied Oral Science - Todo o conteúdo do periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons - Attribution-NonCommercial 3.0 Unported (CC BY-NC 3.0). Fonte: http://www.scielo.br/scielo.php?script=sci_serial&pid=1678-7757&lng=pt&nrm=iso. Acesso em: 20 set. 2013.en
dc.identifier.doihttp://dx.doi.org/10.1590/S1678-77572008000100005en
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.