Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/26572
Arquivos associados a este item:
Arquivo TamanhoFormato 
v82n5a09.pdf303,64 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorResende, Jefferson G.pt_BR
dc.contributor.authorMenezes, Cristiane G.pt_BR
dc.contributor.authorPaula, Ana M. C.pt_BR
dc.contributor.authorFerreira, Antonio C. P.pt_BR
dc.contributor.authorZaconeta, Carlos Alberto Morenopt_BR
dc.contributor.authorSilva, César A. M.pt_BR
dc.contributor.authorRodrigues, Marcelo P.pt_BR
dc.contributor.authorTavares, Paulopt_BR
dc.date.accessioned2017-12-07T04:44:04Z-
dc.date.available2017-12-07T04:44:04Z-
dc.date.issued2006pt_BR
dc.identifier.citationJ. Pediatr. (Rio J.),v.82,n.5,p.359-364,2006pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/26572-
dc.description.abstractOBJETIVO: Avaliar o pico de pressão inspiratória e a freqüência ventilatória obtidos por médicos quando da utilização de balão auto-inflável neonatal em modelo de pulmão. MÉTODOS: Quinze médicos ventilaram simuladores de pulmão de recém-nascidos a termo e pré-termo, sendo os desfechos captados através de um monitor de ventilação. RESULTADOS: As medianas dos picos de pressão foram 23 (intervalo interquartil, 15-47) e 26 (intervalo interquartil, 14-51) cmH2O, sendo menor que 20 em 41,2 e 35,8% das vezes; maior que 40 em 29,7 e 33,6% das vezes e entre 27 e 33 cmH2O em 8,2 e 6,5% das vezes, para o pulmão de termo e de pré-termo, respectivamente. As medianas das freqüências ventilatórias foram de 45 (intervalo interquartil, 36-57) e 48 (intervalo interquartil, 39-55,5) ciclos por minuto, sendo menor que 30 em 9,3 e 6,7% das vezes e maior que 60 em 12 e 13,3% das vezes, respectivamente, para o pulmão de termo e de pré-termo. As diferenças nas medianas não foram estatisticamente significantes. CONCLUSÃO: A ventilação utilizando o balão auto-inflável promoveu adequação para a freqüência ventilatória em aproximadamente 80% das vezes, e os médicos não conseguiram promover ventilação com mínima variabilidade na pressão, alcançando níveis diferentes daqueles definidos no curso de reanimação neonatal em 70% das vezes. Essa situação independeu da ventilação do pulmão-teste análogo ao sistema respiratório de recém-nascidos a termo ou pré-termo.pt_BR
dc.description.abstractOBJECTIVE: To evaluate the peak inspiratory pressure and ventilation rate achieved by physicians when using a neonatal self-inflating bag on a lung model. METHODS: Fifteen physicians ventilated full term and preterm infant lung simulators while the outcomes were captured by a ventilation monitor. RESULTS: Median peak pressures in cmH2O for full term and preterm lungs were 23 (interquartile range: 15-47) and 26 (interquartile range: 14-51), being less than 20 in 41.2 and 35.8% of the pressure curves analyzed, more than 40 in 29.7 and 33.6%, and between 27 and 33 cmH2O in 8.2 and 6.5% of the curves, respectively. Median ventilation rates were 45 (interquartile range: 36-57) and 48 (interquartile range: 39-55.5) cycles per minute, being more than 30 in 9.3 and 6.7% of pressure curves and more than 60 in 12 and 13.3% of pressure curves, for the full term and preterm lungs, respectively. The differences between these medians were not statistically significant. CONCLUSIONS: Ventilation rates achieved with the self-inflating bag were adequate in approximately 80% of pressure curves analyzed, but the physicians were unable to provide ventilation with minimal pressure variation, producing pressures that diverged from those defined by the neonatal resuscitation training course in 70% of the curves. This was irrespective of whether they were ventilating the lung model analogous to preterm or full term infant lungs.pt_BR
dc.language.isoporpt_BR
dc.publisherSociedade Brasileira de Pediatriapt_BR
dc.rightsAcesso Abertopt_BR
dc.titleAvaliação do pico de pressão e da freqüência respiratória durante o uso de balão auto-inflável em um modelo de pulmão neonatalpt_BR
dc.titleEvaluation of peak inspiratory pressure and respiratory rate during ventilation of an infant lung model with a self-inflating bagpt_BR
dc.typeArtigopt_BR
dc.subject.keywordRessuscitação cardiopulmonarpt_BR
dc.subject.keywordVentilação pulmonarpt_BR
dc.subject.keywordVentilação mecânicapt_BR
dc.subject.keywordRecém-nascidospt_BR
dc.subject.keywordAsfixia neonatalpt_BR
dc.identifier.doihttps://dx.doi.org/10.1590/S0021-75572006000600009pt_BR
dc.description.unidadeEm processamento-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.