dc.contributor.authorSposto, Rosa Mariapt_BR
dc.contributor.authorKomeno, Márcio Hissashipt_BR
dc.contributor.authorKrüger, Eduardo Leitept_BR
dc.date.accessioned2017-12-07T04:48:21Z-
dc.date.available2017-12-07T04:48:21Z-
dc.date.issued2007pt_BR
dc.identifier.citationRem: Rev. Esc. Minas,v.60,n.3,p.519-524,2007pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/27035-
dc.description.abstractNesse trabalho, são analisadas alternativas energético-econômicas de paredes de bloco de concreto com preenchimento dos furos do bloco com entulho de demolição para habitações de interesse social. A hipótese do estudo tem como base o aumento da inércia térmica pelo uso do entulho no furo do bloco. Também são analisadas as influências do revestimento e da pintura de branco das paredes. Foram realizadas medições no verão em modelos reduzidos, denominados de test-cells, adotados como alternativa de maior facilidade e de menor custo de construção, comparativamente às habitações em escala real. Após as medições, procedeu-se à calibração do modelo utilizado nas test-cells e, em seguida, foram realizadas simulações de habitações em escala real. Os resultados apontam como sendo a melhor alternativa energético-econômica a solução com bloco de 14 cm de largura com entulho e sem revestimento. Ainda, a pintura na cor branca se mostrou fundamental para a melhoria no desempenho térmico das habitações. Essa alternativa representa uma nova possibilidade para a destinação do entulho de construção, com um menor prejuízo para o meio ambiente, além da economia de energia gerada.pt_BR
dc.description.abstractThis study comprises an energetic and economic feasibility analysis of adding rubble to conventional masonry in low-cost houses. It was assumed that an increase in thermal mass should be expected with the addition of rubble to hollow concrete blocks. The study also analyzes the influence of adding external plaster and white painting to this masonry. Measurements in 1m³ test-cells were carried out during summer, followed by computer simulations in order to calibrate results obtained in the test-cells. After calibration, an ordinary low-cost house was simulated using the same configurations of the experimental part of the study with the purpose of evaluating resulting thermal performance in full scale. Results indicated that the best energetic and economic alternative consists of concrete blocks with 14 cm width with rubble internally and no plaster externally. It was also observed an improvement in the thermal performance of the simulated building with the white painting. Next to an improvement in thermal performance, a new possibility is presented regarding a proper destination of rubble from civil construction.pt_BR
dc.language.isoporpt_BR
dc.publisherEscola de Minaspt_BR
dc.rightsAcesso Abertopt_BR
dc.titleViabilidade energético-econômica de habitações de interesse social em Brasília com uso de blocos de concreto e entulhopt_BR
dc.titleEconomic-energetic feasibility study of the utilization of hollow concrete blocks with rubble in low-cost housing in Brasiliapt_BR
dc.typeArtigopt_BR
dc.subject.keywordDesempenho térmicopt_BR
dc.subject.keywordutilização de entulho de obrapt_BR
dc.subject.keywordMonitoramento térmicopt_BR
dc.subject.keywordCélulas-testept_BR
dc.identifier.doihttps://dx.doi.org/10.1590/S0370-44672007000300013pt_BR
dc.description.unidadeEm processamento-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.