dc.contributor.authorDobranszki, A.pt_BR
dc.contributor.authorLevy Neto, F.pt_BR
dc.contributor.authorDobranszki, N.C.pt_BR
dc.contributor.authorVuolo, J.H.pt_BR
dc.contributor.authorLaboissière Jr., M.A.pt_BR
dc.date.accessioned2017-12-07T04:54:37Z-
dc.date.available2017-12-07T04:54:37Z-
dc.date.issued2010pt_BR
dc.identifier.citationMatéria (Rio J.),v.15,n.3,p.405-412,2010pt_BR
dc.identifier.urihttp://repositorio.unb.br/handle/10482/27874-
dc.description.abstractO objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.pt_BR
dc.description.abstractThe objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.pt_BR
dc.language.isoptpt_BR
dc.publisherRede Latino-Americana de Materiaispt_BR
dc.rightsAcesso Abertopt_BR
dc.titleDistribuição de tensões em mini-implantes ortodônticospt_BR
dc.titleStress distribution in orthodontic mini-implantspt_BR
dc.typeArtigopt_BR
dc.subject.keyworddistribuição de tensõespt_BR
dc.subject.keywordfotoelasticidadept_BR
dc.subject.keywordmini-implantespt_BR
dc.subject.keywordancoragem absolutapt_BR
dc.subject.keywordstress distributionpt_BR
dc.subject.keywordphotoelasticitypt_BR
dc.subject.keywordmini-implantspt_BR
dc.subject.keywordabsolute anchoragept_BR