Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/40765
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_EffectQuadricepsMuscle.pdf1,5 MBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCavalcante, Jonathan Galvão Tenório-
dc.contributor.authorMarqueti, Rita de Cássia-
dc.contributor.authorGeremia, Jeam Marcel-
dc.contributor.authorSousa Neto, Ivo Vieira de-
dc.contributor.authorBaroni, Bruno Manfredini-
dc.contributor.authorSilbernagel, Karin Gravare-
dc.contributor.authorBottaro, Martim-
dc.contributor.authorBabault, Nicolas-
dc.contributor.authorDurigan, João Luiz Quagliotti-
dc.date.accessioned2021-05-03T13:25:08Z-
dc.date.available2021-05-03T13:25:08Z-
dc.date.issued2021-03-29-
dc.identifier.citationCAVALCANTE, Jonathan Galvão Tenório et al. The effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffness. Frontiers in Physiology, v. 12, 633589, 29 mar. 2021. DOI: 10.3389/fphys.2021.633589. Disponível em: https://www.frontiersin.org/articles/10.3389/fphys.2021.633589/full. Acesso em: 03 maio 2021.pt_BR
dc.identifier.urihttps://repositorio.unb.br/handle/10482/40765-
dc.language.isoInglêspt_BR
dc.publisherFrontierspt_BR
dc.rightsAcesso Abertopt_BR
dc.titleThe effect of quadriceps muscle length on maximum neuromuscular electrical stimulation evoked contraction, muscle architecture, and tendon-aponeurosis stiffnesspt_BR
dc.typeArtigopt_BR
dc.subject.keywordExercícios - fisiologiapt_BR
dc.subject.keywordEstimulação elétrica neuromuscularpt_BR
dc.subject.keywordQuadrícepspt_BR
dc.subject.keywordTendõespt_BR
dc.rights.licenseCopyright © 2021 Cavalcante, Marqueti, Geremia, Sousa Neto, Baroni, Silbernagel, Bottaro, Babault and Durigan. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.pt_BR
dc.identifier.doi10.3389/fphys.2021.633589pt_BR
dc.description.abstract1Muscle-tendon unit length plays a crucial role in quadriceps femoris muscle (QF) physiological adaptation, but the influence of hip and knee angles during QF neuromuscular electrical stimulation (NMES) is poorly investigated. We investigated the effect of muscle length on maximum electrically induced contraction (MEIC) and current efficiency. We secondarily assessed the architecture of all QF constituents and their tendon-aponeurosis complex (TAC) displacement to calculate a stiffness index. This study was a randomized, repeated measure, blinded design with a sample of twenty healthy men aged 24.0 ± 4.6. The MEIC was assessed in four different positions: supine with knee flexion of 60° (SUP60); seated with knee flexion of 60° (SIT60); supine with knee flexion of 20° (SUP20), and seated with knee flexion of 20° (SIT20). The current efficiency (MEIC/maximum tolerated current amplitude) was calculated. Ultrasonography of the QF was performed at rest and during NMES to measure pennation angle (θp) and fascicle length (Lf), and the TAC stiffness index. MEIC and current efficiency were greater for SUP60 and SIT60 compared to SUP20 and SIT20. The vastus lateralis and medialis showed lower θp and higher Lf at SUP60 and SIT60, while for the rectus femoris, in SUP60 there were lower θp and higher Lf than in all positions. The vastus intermedius had a similar pattern to the other vastii, except for lack of difference in θp between SIT60 compared to SUP20 and SIT20. The TAC stiffness index was greater for SUP60. We concluded that NMES generate greater torque and current efficiency at 60° of knee flexion, compared to 20°. For these knee angles, lengthening the QF at the hip did not promote significant change. Each QF constituent demonstrated muscle physiology patterns according to hip and/or knee angles, even though a greater Lf and lower θp were predominant in SUP60 and SIT60. QF TAC index stiffened in more elongated positions, which probably contributed to enhanced force transmission and slightly higher torque in SUP60. Our findings may help exercise physiologist better understand the impact of hip and knee angles on designing more rational NMES stimulation strategies.pt_BR
dc.description.unidadeFaculdade de Educação Física (FEF)-
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.