Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio2.unb.br/jspui/handle/10482/47608
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_NumericalSafetyPerformance.pdf1,35 MBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorInojosa, Leonardo da Silveira Pirillo-
dc.contributor.authorBuzar, Márcio Augusto Roma-
dc.contributor.authorPaula, José Humberto Matias de-
dc.contributor.authorSilva, Lenildo Santos da-
dc.date.accessioned2024-01-31T11:55:04Z-
dc.date.available2024-01-31T11:55:04Z-
dc.date.issued2023-10-11-
dc.identifier.citationINOJOSA, Leonardo da Silveira Pirillo et al. Numerical safety and performance analysis of a multipurpose building’s structure : case study. Concilium, [S. l.], v. 23, n. 19, p. 87–99, 2023. DOI: https://doi.org/10.53660/CLM-2070-23P19. Disponível em: https://clium.org/index.php/edicoes/article/view/2070. Acesso em: 31 jan. 2024.pt_BR
dc.identifier.urihttp://repositorio2.unb.br/jspui/handle/10482/47608-
dc.description.abstractÉ apresentado um estudo de caso de um edifício multiuso situado em Brasília-DF. O modelo estrutural do edifício é composto por elementos de um pórtico espacial e placa de quatro nós, medindo 25,75 por 25,75 m com uma altura de 11,65 m. A estrutura é apoiada em pilares rotulados. O piso térreo tem o pé direito de 3,25 m e os outros andares de 2,80 m. O fechamento é feito de alvenaria de tijolo furado. Neste artigo, análises numéricas foram realizadas utilizando o software SAP2000 para verificar o deslocamento, deformação e tensão da estrutura. O estudo seguiu os critérios de estado limite último e de uso para a norma brasileira de concreto armado (NBR 6118). São apresentadas as patologias estruturais do prédio, detectadas por meio de inspeção visual. Os principais elementos estruturais e suas respectivas patologias são descritos, e ensaios numéricos são mostrados. Devido à presença de várias fissuras e outras patologias na edificação, uma análise de instabilidade elástica foi realizada usando o modelo de análise de Rankine-Marchant para verificar o fator de carga de colapso. Após cerca de 17 anos de uso, o edifício é revisitado para avaliar a durabilidade e o desempenho dos componentes e procedimentos estruturais propostos.pt_BR
dc.language.isoengpt_BR
dc.publisherConcilium Journalpt_BR
dc.rightsAcesso Abertopt_BR
dc.titleNumerical safety and performance analysis of a multipurpose building’s structure : case studypt_BR
dc.title.alternativeAnálise numérica de segurança e desempenho da estrutura de edifício multiuso : estudo de casopt_BR
dc.typeArtigopt_BR
dc.subject.keywordPatologia das construçõespt_BR
dc.subject.keywordInstabilidade elásticapt_BR
dc.subject.keywordAnálise estruturalpt_BR
dc.rights.license(CC BY NC SA) Published under the following license: Atribuição-Não-Comercial-Compartilhamento. Fonte: https://clium.org/index.php/edicoes/article/view/2070. Acesso em: 31 jan. 2024.pt_BR
dc.identifier.doihttps://doi.org/10.53660/CLM-2070-23P19pt_BR
dc.description.abstract1This report presents a case study of a multi-use building situated in Brasília-DF. The building's structural model is made up of elements of a spatial portico and four-knot plate, measuring 25.75 by 25.75 m with a height of 11.65 m. The structure is supported by rotating pillars at the base. The ground floor has a ceiling height of 3.25 m, while the other floors have a ceiling height of 2.80 m. The closure is made of bored brick masonry. In this article, numerical analyses were conducted using the SAP2000 structural software to verify the structure's displacement, deformation, and stress. The study followed the ultimate and in-use limit state criteria for the Brazilian standard of reinforced concrete (NBR 6118). The report also presents the building's structural pathologies, detected through visual inspection. The main structural elements and their respective pathologies are described, and numerical tests are shown. Due to the presence of various cracks and other pathologies in the building, an elastic instability analysis was conducted using the Rankine-Marchant analysis model to verify the collapse load factor. After approximately 17 years of use, the building is revisited to assess the durability and performance of the recovered structural components and procedures.pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0003-0745-6900pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-1164-2784pt_BR
dc.identifier.orcidhttps://orcid.org/0009-0009-4697-9254pt_BR
dc.identifier.orcidhttps://orcid.org/0000-0001-5099-6123pt_BR
dc.contributor.affiliationUniversidade de Brasília, Departamento de Engenharia Civil e Ambientalpt_BR
dc.contributor.affiliationUniversidade de Brasília, Faculdade de Arquitetura e Urbanismopt_BR
dc.contributor.affiliationUniversidade de Brasília, Departamento de Engenharia Civil e Ambientalpt_BR
dc.contributor.affiliationUniversidade de Brasília, Departamento de Engenharia Civil e Ambientalpt_BR
dc.description.unidadeFaculdade de Tecnologia (FT)pt_BR
dc.description.unidadeDepartamento de Engenharia Civil e Ambiental (FT ENC)pt_BR
dc.description.unidadeFaculdade de Arquitetura e Urbanismo (FAU)pt_BR
dc.description.unidadeDepartamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)pt_BR
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.