Campo DC | Valor | Idioma |
dc.contributor.author | Inojosa, Leonardo da Silveira Pirillo | - |
dc.contributor.author | Buzar, Márcio Augusto Roma | - |
dc.contributor.author | Paula, José Humberto Matias de | - |
dc.contributor.author | Silva, Lenildo Santos da | - |
dc.date.accessioned | 2024-01-31T11:55:04Z | - |
dc.date.available | 2024-01-31T11:55:04Z | - |
dc.date.issued | 2023-10-11 | - |
dc.identifier.citation | INOJOSA, Leonardo da Silveira Pirillo et al. Numerical safety and performance analysis of a multipurpose building’s structure : case study. Concilium, [S. l.], v. 23, n. 19, p. 87–99, 2023. DOI: https://doi.org/10.53660/CLM-2070-23P19. Disponível em: https://clium.org/index.php/edicoes/article/view/2070. Acesso em: 31 jan. 2024. | pt_BR |
dc.identifier.uri | http://repositorio2.unb.br/jspui/handle/10482/47608 | - |
dc.description.abstract | É apresentado um estudo de caso de um edifício multiuso situado em Brasília-DF. O modelo estrutural do
edifício é composto por elementos de um pórtico espacial e placa de quatro nós, medindo 25,75 por 25,75
m com uma altura de 11,65 m. A estrutura é apoiada em pilares rotulados. O piso térreo tem o pé direito de
3,25 m e os outros andares de 2,80 m. O fechamento é feito de alvenaria de tijolo furado. Neste artigo,
análises numéricas foram realizadas utilizando o software SAP2000 para verificar o deslocamento,
deformação e tensão da estrutura. O estudo seguiu os critérios de estado limite último e de uso para a norma
brasileira de concreto armado (NBR 6118). São apresentadas as patologias estruturais do prédio, detectadas
por meio de inspeção visual. Os principais elementos estruturais e suas respectivas patologias são descritos,
e ensaios numéricos são mostrados. Devido à presença de várias fissuras e outras patologias na edificação,
uma análise de instabilidade elástica foi realizada usando o modelo de análise de Rankine-Marchant para
verificar o fator de carga de colapso. Após cerca de 17 anos de uso, o edifício é revisitado para avaliar a
durabilidade e o desempenho dos componentes e procedimentos estruturais propostos. | pt_BR |
dc.language.iso | eng | pt_BR |
dc.publisher | Concilium Journal | pt_BR |
dc.rights | Acesso Aberto | pt_BR |
dc.title | Numerical safety and performance analysis of a multipurpose building’s structure : case study | pt_BR |
dc.title.alternative | Análise numérica de segurança e desempenho da estrutura de edifício multiuso : estudo de caso | pt_BR |
dc.type | Artigo | pt_BR |
dc.subject.keyword | Patologia das construções | pt_BR |
dc.subject.keyword | Instabilidade elástica | pt_BR |
dc.subject.keyword | Análise estrutural | pt_BR |
dc.rights.license | (CC BY NC SA) Published under the following license: Atribuição-Não-Comercial-Compartilhamento. Fonte: https://clium.org/index.php/edicoes/article/view/2070. Acesso em: 31 jan. 2024. | pt_BR |
dc.identifier.doi | https://doi.org/10.53660/CLM-2070-23P19 | pt_BR |
dc.description.abstract1 | This report presents a case study of a multi-use building situated in Brasília-DF. The building's structural
model is made up of elements of a spatial portico and four-knot plate, measuring 25.75 by 25.75 m with a
height of 11.65 m. The structure is supported by rotating pillars at the base. The ground floor has a ceiling
height of 3.25 m, while the other floors have a ceiling height of 2.80 m. The closure is made of bored brick
masonry. In this article, numerical analyses were conducted using the SAP2000 structural software to verify
the structure's displacement, deformation, and stress. The study followed the ultimate and in-use limit state
criteria for the Brazilian standard of reinforced concrete (NBR 6118). The report also presents the building's
structural pathologies, detected through visual inspection. The main structural elements and their respective
pathologies are described, and numerical tests are shown. Due to the presence of various cracks and other
pathologies in the building, an elastic instability analysis was conducted using the Rankine-Marchant
analysis model to verify the collapse load factor. After approximately 17 years of use, the building is
revisited to assess the durability and performance of the recovered structural components and procedures. | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0003-0745-6900 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0002-1164-2784 | pt_BR |
dc.identifier.orcid | https://orcid.org/0009-0009-4697-9254 | pt_BR |
dc.identifier.orcid | https://orcid.org/0000-0001-5099-6123 | pt_BR |
dc.contributor.affiliation | Universidade de Brasília, Departamento de Engenharia Civil e Ambiental | pt_BR |
dc.contributor.affiliation | Universidade de Brasília, Faculdade de Arquitetura e Urbanismo | pt_BR |
dc.contributor.affiliation | Universidade de Brasília, Departamento de Engenharia Civil e Ambiental | pt_BR |
dc.contributor.affiliation | Universidade de Brasília, Departamento de Engenharia Civil e Ambiental | pt_BR |
dc.description.unidade | Faculdade de Tecnologia (FT) | pt_BR |
dc.description.unidade | Departamento de Engenharia Civil e Ambiental (FT ENC) | pt_BR |
dc.description.unidade | Faculdade de Arquitetura e Urbanismo (FAU) | pt_BR |
dc.description.unidade | Departamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC) | pt_BR |
Aparece nas coleções: | Artigos publicados em periódicos e afins
|