Skip navigation
Use este identificador para citar ou linkar para este item: http://repositorio.unb.br/handle/10482/49057
Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_AdaptiveThermalComfort.pdf620,02 kBAdobe PDFVisualizar/Abrir
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorSilva, Caio Frederico e-
dc.contributor.authorLopes, Adriano Felipe Oliveira-
dc.contributor.authorGóes, Thiago Montenegro-
dc.contributor.authorAmorim, Cláudia Naves David-
dc.date.accessioned2024-07-19T13:04:11Z-
dc.date.available2024-07-19T13:04:11Z-
dc.date.issued2020-
dc.identifier.citationSILVA, Caio Frederico e et al. Adaptive thermal comfort in Brazilian schools by Building Performance Simulation (BPS). Journal of Civil Engineering and Architecture, [S. l.], v. 14, p. 174-178, 2020. DOI: https://doi.org/10.17265/1934-7359/2020.03.007. Disponível em: https://www.davidpublisher.com/index.php/Home/Article/index?id=42715.html. Acesso em; 19 jul. 2024.pt_BR
dc.identifier.urihttp://repositorio2.unb.br/jspui/handle/10482/49057-
dc.language.isoengpt_BR
dc.publisherDavid Publishingpt_BR
dc.rightsAcesso Abertopt_BR
dc.titleAdaptive thermal comfort in Brazilian schools by Building Performance Simulation (BPS)pt_BR
dc.typeArtigopt_BR
dc.subject.keywordConforto térmicopt_BR
dc.subject.keywordSimulação (Computadores)pt_BR
dc.subject.keywordEscolaspt_BR
dc.rights.license(CC BY NC) This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License. Fonte: https://www.davidpublisher.com/index.php/Home/Article/index?id=42715.html. Acesso em: 19 jul. 2024.pt_BR
dc.identifier.doihttps://doi.org/10.17265/1934-7359/2020.03.007pt_BR
dc.description.abstract1Building performance simulation (BPS) is a crucial tool towards the design of projects better adapted its climatic context. In this sense, the objective of this research is to evaluate a method of thermal comfort analysis of schools in three Brazilian cities using BPS. The methodological procedures involved a literature review, in which the simulation tool and analysis method were chosen. Following simulations with the software DesignBuilder were performed using as study case a standard school typology designed by the General Coordination of Educational Infrastructure (CODIN/FNDE). This article evaluates its percentage occupied comfort hours in 3 reference cities: Cuiabá-MT, Brasília-DF, and Curitiba-PR. The results show respectively, for the cities of Curitiba, Brasília and Cuiabá, percentages of comfort hours of 76%, 70%, and 23%. The research states that the project must have different strategies for different climates. Finally, this article recommends this method should be applied to other cities and buildings.pt_BR
dc.contributor.affiliationUniversity of Brasíliapt_BR
dc.contributor.affiliationUniversity of Brasíliapt_BR
dc.contributor.affiliationUniversity of Brasíliapt_BR
dc.contributor.affiliationUniversity of Brasíliapt_BR
dc.description.unidadeFaculdade de Arquitetura e Urbanismo (FAU)pt_BR
dc.description.unidadeDepartamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)pt_BR
dc.description.ppgPrograma de Pós-Graduação em Arquitetura e Urbanismopt_BR
Aparece nas coleções:Artigos publicados em periódicos e afins

Mostrar registro simples do item Visualizar estatísticas



Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.