Campo DC | Valor | Idioma |
dc.contributor.advisor | Melo, Guilherme Sales Soares de Azevedo | - |
dc.contributor.author | Oliveira, Marcos Honorato de | - |
dc.date.accessioned | 2013-07-19T17:30:34Z | - |
dc.date.available | 2013-07-19T17:30:34Z | - |
dc.date.issued | 2013-07-19 | - |
dc.date.submitted | 2013-03 | - |
dc.identifier.citation | OLIVEIRA, Marcos Honorato de. Punção em lajes lisas com armadura de cisalhamento submetidas a carregamento excêntrico e apoiadas sobre pilares retangulares. 2013. xxvii, 223 f., il. Tese (Doutorado em Estruturas e Construção Civil)—Universidade de Brasília, Brasília, 2013. | en |
dc.identifier.uri | http://repositorio.unb.br/handle/10482/13624 | - |
dc.description | Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2013. | en |
dc.description.abstract | O fenômeno de punção em lajes lisas é um fator determinante na elaboração e nas verificações de projeto deste tipo de sistema construtivo. Quando a ligação laje-pilar está submetida a carregamento excêntrico o número de variáveis envolvidas na formulação é consideravelmente maior em relação à situação de carregamento simétrico, o que aparentemente reduz a precisão do método de verificação para este caso. O emprego da armadura de cisalhamento é uma solução bastante utilizada para aumentar a resistência à punção da ligação laje-pilar. É com base nestas informações que este trabalho propõe um estudo de lajes lisas com e sem utilização de armadura de cisalhamento submetidas a carregamento simétrico ou excêntrico. Foram analisadas experimentalmente dezesseis modelos locais de laje lisa apoiada sobre um pilar retangular interno. As lajes foram armadas ao cisalhamento com armadura do tipo double-headed stud e submetidas a carregamento simétrico e excêntrico. As lajes possuíam dimensões quadradas com 2500 mm de lado e 180 mm de espessura, moldadas com concreto usinado de resistência média em torno de 50 MPa. O pilar de cada modelo possuía seção transversal com dimensões retangulares de 200mm por 400mm. As principais variáveis de ensaio foram a utilização ou não de armadura de cisalhamento, a taxa de armadura de cisalhamento, o número de camadas da armadura de cisalhamento, o tipo de carregamento (simétrico ou excêntrico) e o eixo de flexão dos modelos submetidos ao carregamento excêntrico. São apresentados os resultados de carga última, dos deslocamentos verticais, das deformações na armadura de flexão, das deformações na armadura de cisalhamento, das deformações no concreto e também a posição e inclinação da superfície de ruptura das lajes e o mapa de fissuração de cada laje. Os resultados experimentais coletados foram adicionados a um banco de dados criado para uma análise de desempenho das recomendações sobre a verificação da resistência à punção de algumas normas de projeto. As normas analisadas foram: NBR 6118 (2007), Eurocode 2 (2004), ACI 318M (2008) e também foram avaliadas as prescrições utilizadas para as estimativas de resistência à punção da Teoria da Fissura Crítica de Cisalhamento (TFCC). Algumas das principais contribuições deste trabalho foram a adaptação do Método da Superfície de Resistência Mínima (MSRM) para o caso de lajes submetidas a carregamento simétrico e a proposta de uma nova formulação para este método no caso de lajes submetidas a carregamento excêntrico. _______________________________________________________________________________________ ABSTRACT | en |
dc.description.abstract | The punching shear phenomenon in flat slabs is a main factor in the design of this type of structural system. When the slab-column connection is subjected to eccentric loading the number of involved variables in the formulation is considerably higher if compared to the situation of symmetrical loading, which apparently reduces the accuracy of the verification method for this case. The use of shear reinforcement is a solution often used to increase the punching shear strength in the slab-column connection. It is based on these information that this work proposes a study of the use of flat slabs with shear reinforcement and subjected to symmetrical and eccentric loading. Sixteen local models of flat slab supported on a rectangular internal column were tested. The slabs had shear reinforcement consisting of double-headed studs and were subjected to symmetrical and eccentric loading. The slabs had square dimensions with a side of 2,500 mm and with a thickness of 180 mm, casted concrete with average compressive strength around 50MPa. The column of each model had rectangular dimensions: 200 mm wide by 400 mm long. The principal test’s variables were the use of shear reinforcement, the rate of shear reinforcement, the number of layers of shear reinforcement, the type of load (symmetrical or eccentric) and the bending axis in the case of to eccentric loading . The results consist of vertical displacements of the slabs, strains in the bending and shear reinforcement, strains on the concrete and also the position and inclination of the failure surface of the slabs and cracking map of each slab. The experimental results collected were added to a database created for a comparative analysis of design code recommendations on punching shear strength. The codes analyzed were: NBR 6118 (2007), Eurocode 2 (2004), ACI 318M (2008) .The procedure used to estimate the ultimate punching shear strength of the Critical Shear Crack Theory (CSCT) was also evaluated. Some of the main contributions of this work were an adaptation of Surface of Minimum Shear Resistance (SMSR) for the case of slabs subjected to symmetrical loading and a new formulation for this method in the case of slabs subjected to eccentric loading. | en |
dc.language.iso | Português | en |
dc.rights | Acesso Aberto | en |
dc.title | Punção em lajes lisas com armadura de cisalhamento submetidas a carregamento excêntrico e apoiadas sobre pilares retangulares | en |
dc.type | Tese | en |
dc.subject.keyword | Concreto armado | en |
dc.subject.keyword | Deformações e tensões | en |
dc.subject.keyword | Blocos de concreto | en |
dc.subject.keyword | Lajes - concreto | - |
dc.subject.keyword | Lajes lisas | en |
dc.rights.license | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. | en |
dc.description.unidade | Faculdade de Tecnologia (FT) | pt_BR |
dc.description.unidade | Departamento de Engenharia Civil e Ambiental (FT ENC) | pt_BR |
dc.description.ppg | Programa de Pós-Graduação em Estruturas e Construção Civil | pt_BR |
Aparece nas coleções: | Teses, dissertações e produtos pós-doutorado
|