http://repositorio.unb.br/handle/10482/15390
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
2013_WanderleyGustavoNicacio.pdf | 10,5 MB | Adobe PDF | Visualizar/Abrir |
Título : | Reforço à punção em lajes lisas de concreto armado com polímeros reforçados com fibra de carbono |
Otros títulos : | Punching strengthening in flat plates of reinforced concrete with carbon fiber reinforced polymer |
Autor : | Nicácio, Wanderley Gustavo |
Orientador(es):: | Melo, Guilherme Sales Soares de Azevedo |
Assunto:: | Lajes - concreto Polímeros Fibras de carbono Lajes lisas |
Fecha de publicación : | 27-mar-2014 |
Data de defesa:: | ago-2013 |
Citación : | NICÁCIO, Wanderley Gustavo. Reforço à punção em lajes lisas de concreto armado com polímeros reforçados com fibra de carbono. 2013. xix, 136 f., il. Dissertação(Mestrado em Estruturas e Construção Civil)—Universidade de Brasília, Brasília, 2013. |
Resumen : | Esta pesquisa avalia experimentalmente o comportamento da ligação laje-pilar, num sistema de lajes lisas de concreto armado, localizadas internamente à edificação e submetidas a carregamento simétrico, reforçadas ao cisalhamento com polímeros de fibra de carbono (PRFC). O método de reforço consiste em se aplicar a manta de PRFC como elemento resistente ao cisalhamento, por meio de sua colagem através de furos perpendiculares ao plano da laje. Neste estudo experimental, foram realizados oito modelos de lajes lisas com dimensões de 2500 x 2500 mm de comprimento, altura nominal de 180 mm, pilares quadrados centrados com dimensão de 300 mm e mesma taxa da armadura, variando-se: a técnica de reforço, distribuição dos furos, número e área de reforço por camada. A manta de PRFC foi aplicada com a adaptação da técnica Dowel, similar a armaduras do tipo pino, e por meio da técnica Stitch que se assemelha a estribos fechados. Os resultados dos ensaios foram analisados quanto a deslocamentos verticais, deformação específica no concreto, no aço e na armadura de cisalhamento, carga, fissuração, superfície e modo de ruptura. Como as normas atuais não tratam do reforço ao cisalhamento com armaduras de cisalhamento do tipo PRFC, foi avaliada a aplicação de prescrições estabelecidas pelo ACI 318 (2011), Eurocode 2 (2004) e ABNT NBR 6118 (2007), associadas com as limitações do ACI 440.2R (2008) que trata da aplicação dos materiais de PRF. ______________________________________________________________________________________ ABSTRACT This research experimentally evaluates the behavior of slab-column connections in a reinforced concrete flat slab system, internally located in the building and subjected to symmetrical loading, strengthened to the shear with carbon fiber reinforced polymer (CFRP). The strengthening method consists in applying CFRP sheet as shear resistant element, by bonding it through perpendicular holes to the plane of the slab. This experimental study consisted of tests on eight flat slab models with the following dimensions 2500 x 2500 mm length, trickness of 180 mm, supported on centered square cross section columns of 300 mm side and same flexural reinforcement ratio, using the following variations: the strengthening technique, the pattern of holes and the number of peripheral lines of the shear reinforcement. The CFRP sheet was applied with an adaptation of the Dowel technique, was used, which is similar to shear studs, and the stitch technique, which resembles closed stirrups. The test results were examined by verifying the vertical displacements, the concrete, steel and shear reinforcement strains, ultimate loads, cracking patterns, surface and failure modes. As the current standards do not deal with strengthening to shear with CFRP reinforcement, it was assessed the application of the code’s required from by ACI 318 (2011), by Eurocode 2 (2004) and by ABNT NBR 6118 (2007), associated to the limitations of ACI 440.2R (2008) which provides guidance for the selection, design, and installation of FRP systems for concrete structures. |
metadata.dc.description.unidade: | Faculdade de Tecnologia (FT) Departamento de Engenharia Civil e Ambiental (FT ENC) |
Descripción : | Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, 2013. |
metadata.dc.description.ppg: | Programa de Pós-Graduação em Estruturas e Construção Civil |
Licença:: | A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data. |
Aparece en las colecciones: | Teses, dissertações e produtos pós-doutorado |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.