Citation: LIMA, Henrique Jorge Nery de. Análise experimental da punção de lajes lisas tipo Bubbledeck. 2015. xx, 113 f., il. Dissertação (Mestrado em Estruturas e Construção Civil)—Universidade de Brasília, Brasília, 2015.
Abstract: Esta pesquisa avalia experimentalmente o comportamento da ligação laje-pilar, localizadas internamente à edificação em um sistema de lajes lisas de concreto armado, de uma recente técnica construtiva de lajes de concreto armado, denominada Bubbledeck. Essa técnica consiste em um método construtivo composto pela adição de esferas plásticas em lajes de concreto armado, uniformemente espaçadas entre duas telas de aço, com uso cada vez mais frequente em países como Holanda, Austrália, Estados Unidos, Canadá, Reino Unido e Dinamarca. Foram analisadas quatro modelos de lajes nesse estudo experimental, três lajes do tipo Bubbledeck e uma laje maciça de referência, todas as lajes possuem dimensões de 2500 x 2500 mm de comprimento, altura nominal com 280 mm, pilar circular com 300 mm de diâmetro e mesma taxa de armadura. Os parâmetros variados foram: método construtivo, utilização ou não de pré-laje; e utilização de armadura de cisalhamento. Os pontos analisados nos resultados experimentais foram: os deslocamentos verticais, deformações na superfície do concreto, deformações na armadura de flexão e cisalhamento, fissuração e o modo de ruptura de cada laje. Os dados experimentais foram comparados com os métodos teóricos estabelecidos em normas de projeto. As normas avaliadas foram: o ACI 318 (2011), o Eurocode 2 (2010) e a NBR 6118 (2014). Uma vez que nenhuma destas normas não tratam desse sistema construtivo de lajes Bubbledeck, foi proposta uma adaptação na determinação da área de concreto a ser considerada na seção do perímetro crítico. Verificou-se que o método construtivo não interferiu de forma considerável na resistência ao cisalhamento na ligação laje-pilar das lajes Bubbledeck e que a armadura de cisalhamento adotada mesmo conferindo maior ductilidade à laje, também não conferiu maior incremento de resistência à punção.
Abstract: This research experimentally evaluates the behavior of slab-column connection, internally located at the building, in a reinforced concrete flat slabs system, a recent construction technique of reinforced concrete slabs, called Bubbledeck. This technique consists of new constructive method comprises the addition of plastic balls in reinforced concrete slabs, evenly spaced between two steel screens. Its use is increasingly common in countries like the Netherlands, Australia, USA, Canada, UK and Denmark. Four slabs models were analyzed in this experimental study (three Bubbledeck type and a reference solid), all of the slabs have dimensions of 2500 x 2500 mm length, nominal height of 280 mm, centered circular cross section column of 300 mm diameter and the same flexural reinforcement ratio. The varied parameters in Bubbledeck slabs were: construction method, use or not of pre-slab; and use of shear reinforcement. The points analyzed the experimental results were: vertical displacements, strains in the concrete surface deformations in the armor of bending and shear cracking and failure mode of each slab. The experimental data were compared with the theoretical methods established in design codes. The codes were evaluated: ACI 318 (2011), the Eurocode 2 (2010) and the NBR 6118 (2014). Since none of these codes do not address this constructive system Bubbledeck slabs, proposed an adaptation in determining the concrete area to be considered in the critical section perimeter. It was found that the construction method did not affect considerably the shear strength of the slab-column connection of Bubbledeck slabs and shear reinforcement adopted even giving greater ductility to the slab, also did not confer greater resistance to increase the punching.
metadata.dc.description.unidade: Faculdade de Tecnologia (FT)
Departamento de Engenharia Civil e Ambiental (FT ENC)
Description: Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015.
metadata.dc.description.ppg: Programa de Pós-Graduação em Estruturas e Construção Civil
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
DOI: http://dx.doi.org/10.26512/2015.03.D.18978
Appears in Collections:Teses, dissertações e produtos pós-doutorado

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/18978/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.