Title: Dynamic response analysis of the electro-pneumatic module of a continuous positive airway pressure in newborns using Bond Graph modeling
Other Titles: Análise de resposta dinâmica do módulo eletro-pneumático da pressão positiva contínua na via aérea modelado por Bond Graph
Authors: Rosa, Suélia de Siqueira Rodrigues Fleury
Assunto:: CPAP
Modelagem
Bond graph
Issue Date: 2015
Publisher: Unisinos
Citation: ROSA, Suélia Siqueira Rodrigues Fleury. Análise de resposta dinâmica do módulo eletro-pneumático da pressão positiva contínua na via aérea modelado por Bond Graph. Estudos Tecnológicos em Engenharia, v. 10, n. 2, p. 57-63, 2015. Disponível em: <http://revistas.unisinos.br/index.php/estudos_tecnologicos/article/view/ete.2014.102.02/4609>. Acesso em: 07 out. 2016.
Abstract: O Continuous Positive Airway Pressure (CPAP) é um sistema de ventilação não invasiva complexo, atualmente aplicado particularmente em neonatologia. Nesse contexto, os parâmetros devem ser controlados, pois terão um impacto sobre a sobrevivência de prematuros com muito baixo peso ao nascer – que requerem um controle constante. O objetivo deste artigo foi propor um modelo matemático para o Módulo de eletro-pneumático de um sistema CPAP em recém-nascidos (Neo-CPAP) com o interesse em verificar rapidamente a influência de uma determinada alteração de parâmetro sobre o desempenho dos subsistemas. A metodologia utilizada para análise das variáveis foi a da modelagem matemática pela técnica IDOV (validar, identifi car, projetar, otimizar). Tal abordagem leva a uma modelagem adequada para a obtenção do comportamento físico e da caracterização do sistema estudado. O conjunto de resultados do sistema que realiza a função CPAP foi obtido; a pesquisa mostrou que, através da adoção de um propósito específi co, pode-se criar uma melhor compreensão da Tecnologia Assistiva e de seus parâmetros e de como controlá-los.
Abstract: Continuous Positive Airway Pressure is a ventilation system noninvasive complex currently applied in particular in neonatology. In this context, the parameters must have a controlled sett ing, since it will have an impact on the survival of premature infants with very low birth weight - which require constant control. The aim of this paper was to propose a mathematical model for the electro-pneumatic module of a Continuous Positive Airway Pressure in newborns system (Neo CPAP) with an interest in quickly check the infl uence of a particular change parameter on the performance of subsystems. The methodology used to analyze the variables was the mathematical modeling by IDOV technique (validate, identify, design, optimize). This approach leads to an adequate shape for obtaining the physical behavior and characterization of the studied system. The joint system accomplishes results that CPAP function is obtained; research has shown that, by adopting a specifi c purpose, one can create a better understanding of Assistive Technology and its parameters and how to control it.
metadata.dc.description.unidade: Faculdade UnB Gama (FGA)
Licença:: Estudos Tecnológicos em Engenharia - Este trabalho está licenciado sob uma Licença Creative Commons Attribution 3.0 Unported (CC BY 3.0). Fonte: http://revistas.unisinos.br/index.php/estudos_tecnologicos/article/view/ete.2014.102.02/4609. Acesso em: 07 out. 2016.
Appears in Collections:Artigos publicados em periódicos e afins

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/21778/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.