Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/31267
Files in This Item:
File Description SizeFormat 
2017_JoãoRenatoCarneirodeAguiar.pdf9,21 MBAdobe PDFView/Open
Title: Desempenho da qualidade do ar em estudos de caso de ambientes hospitalares no contexto climático de Brasília – DF
Authors: Aguiar, João Renato Carneiro de
Orientador(es):: Silva, Caio Frederico e
Assunto:: Ar - qualidade
Ventilação natural
Hospitais
Saúde
Ambiente de instituições de saúde
Issue Date: 20-Feb-2018
Citation: AGUIAR, João Renato Carneiro de. Desempenho da qualidade do ar em estudos de caso de ambientes hospitalares no contexto climático de Brasília – DF. 2017. xvii, 164 f., il. Dissertação (Mestrado em Arquitetura e Urbanismo)—Universidade de Brasília, Brasília, 2017.
Abstract: Estudos demonstram os efeitos negativos das altas concentrações de partículas indesejadas no ar para a saúde humana. Normas vigentes da área de saúde preconizam a utilização de equipamentos artificiais para manter a qualidade do ar interno nos ambientes hospitalares, em detrimento de soluções passivas de ventilação. Neste sentido, a presente dissertação aborda o tema da ventilação natural em ambientes de saúde, com o objetivo principal de avaliar a renovação do ar em ambientes hospitalares no contexto climático de Brasília por meio de simulações computacionais. Como estudos de caso foram estudados 5 ambientes hospitalares de Brasília: o Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago e Hospital de Apoio de Brasília. A pesquisa se estruturou a partir da revisão bibliográfica com o uso das normas e legislações específicas; coleta de informações referente aos estudos de caso escolhidos; métodos para a definição da velocidade dos ventos predominantes e, por fim, a realização da simulação pelo processo computacional CFD (Computacional Fluid Dynamics – CFD Autodesk 2015) para analisar o potencial da ventilação natural nos ambientes hospitalares estudados. Os parâmetros para definição da velocidade do vento foram fornecidos pelas normais climatológicas (INMET), pela ficha bioclimática e pela fórmula matemática que avalia condicionantes do terreno e altura das aberturas. Os resultados da pesquisa apontam que o uso da ventilação natural nos ambientes é eficaz na maioria dos casos, sobretudo quando são associados a boa qualidade do ar externo e uma boa análise das condicionantes do entorno (que envolve direção dos ventos predominantes e análise de barreiras urbanas), assim sendo suficiente para promover uma boa qualidade do ar interna.
Abstract: Studies demonstrate the negative effects of high concentrations of unwanted particles in the air for the human health. Currents health standards recommend the use of artificial equipment to maintain indoor air quality in hospital environments, in detriment of passive ventilations solutions. In this sense, the present dissertation aims to disseminate the topic of natural ventilation in health environments, with the main objective of evaluating the air renewal in the hospitals in the climatic context of Brasília by means of computational simulations. The case studies were 5 hospitals environments in Brasília: The Hospital de Base do Distrito Federal, Hospital da Criança de Brasília, Hospital Sarah Centro, Hospital Sarah Lago and Hospital de Apoio de Brasília. The research was structured from the bibliographical review with the use of specific norms and legislation, collection of information regarding the selected case studies, methods for definition of prevailing wind velocity and, finally a simulation performance for the CFD (Computational Fluid Dynamics – CFD Autodesk 2015) process to analyze the potential of natural ventilation in the hospitals studied. The parameters for definition the wind speed is provided by normal climatological (INMET), by bioclimatic chart and by mathematical formula that evaluates terrain conditions and height of the openings. The results of the research indicated that the use of natural ventilation in the health environments is effective in the most cases, especially when good external air quality is associated with a good analysis of the environmental conditions factors (involving predominant winds directions and analysis of urbans barriers), thus being sufficient to promote a good indoor air quality.
Description: Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2017.
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Appears in Collections:Teses, dissertações e produtos pós-doutorado

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/31267/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.