Skip navigation
Please use this identifier to cite or link to this item: http://repositorio.unb.br/handle/10482/38353
Files in This Item:
File Description SizeFormat 
2019_GabrielBarretodosSantos.pdf6,62 MBAdobe PDFView/Open
Title: Avaliação da proteção de distância em linhas de interconexão de complexos eólicos
Authors: Santos, Gabriel Barreto dos
Orientador(es):: Lopes, Felipe Vigolvino
Coorientador(es):: Reis, Alex
Assunto:: Linhas de transmissão
Energia eólica
Issue Date: 29-Jun-2020
Citation: SANTOS, Gabriel Barreto dos. Avaliação da proteção de distância em linhas de interconexão de complexos eólicos. 2019. 117 f., il. Dissertação (Mestrado em Engenharia Elétrica)—Universidade de Brasília, Brasília, 2019.
Abstract: Com o desenvolvimento tecnológico e o elevado nível competitivo na qual as fontes renováveis de energia elétrica atingiram no mercado mundial, tem-se veri_cado um alto índice depenetração dessas fontes no sistema elétrico brasileiro. Neste contexto, a energia eólica tem sido protagonista no desenvolvimento energético nas regiões nordeste e sul do país. Diante do exposto, faz-se necessário avaliar possíveis impactos ocasionados pela inserção destas fontes no sistema elétrico como um todo. Em linha com o descrito, esta dissertação tem como foco de seu estudo, a avaliação do comportamento da proteção de distância quando aplicada a uma linha de transmissão (LT) que interliga parques eólicos com o restante do sistema elétrico. Para realizar tal estudo, foi modelado no Alternative Transients Program (ATP) um sistema teste típico de complexos eólicos, com modelagem full-converter, em operação no Sistema Interligado Nacional (SIN). Diante dos testes avaliados é possível perceber a grande influência dos sinais gerados pelo complexo eólico sobre o funcionamento da proteção de distância.
Abstract: With the technological development and the high competitive level in which renewable sources of electricity reached the world market, a high degree of penetration of these sources in the Brazilian electric system has been veri_ed. In this context, wind energy has been a protagonista in energy development in the northeast and south of the country. Given the above, it is necessary to evaluate possible e_ects caused by the insertion of these sources in the electrical system as a whole. In line with the above, this dissertation focuses on its study, an assessment of the behavior of distance protection when applied to a transmission line (LT) that interconnects wind farms with the rest of the electrical system. To carry out this study, was modeled on Alternative Transients Program (ATP), a typical full-converter wind complex test system operating in the National Interconnected System (SIN). Given the tests evaluated, it is possible to notice the great in_uence of the signals generated by the wind complex on the distance protection operation.
metadata.dc.description.unidade: Faculdade de Tecnologia (FT)
Departamento de Engenharia Elétrica (FT ENE)
metadata.dc.description.ppg: Programa de Pós-Graduação em Engenharia Elétrica
Licença:: A concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.
Appears in Collections:Teses, dissertações e produtos pós-doutorado

Show full item record " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/38353/statistics">



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.