Skip navigation
Veuillez utiliser cette adresse pour citer ce document : http://repositorio2.unb.br/jspui/handle/10482/44715
Fichier(s) constituant ce document :
Il n'y a pas de fichiers associés à ce document.
Titre: Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force
Auteur(s): Couto, Diego
Cunha, Rafael
Lage, Victor
Rocha Júnior, Valdinar de Araújo
Santos, Wanderson
Ferreia Júnior, João
Tufano, James
Vieira, Amilton
metadata.dc.identifier.orcid: https://orcid.org/0000-0003-1328-069X
https://orcid.org/0000-0002-1865-2790
https://orcid.org/0000-0001-6322-9804
https://orcid.org/0000-0001-6973-6006
https://orcid.org/0000-0002-4378-1041
https://orcid.org/0000-0002-7541-8212
https://orcid.org/0000-0001-8325-0344
https://orcid.org/0000-0002-6027-4367
Assunto:: Aptidão muscular
Força muscular
Tração isométrica do meio da coxa (IMTP)
Date de publication: 2022
Référence bibliographique: COUTO, Diego et al. Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force. Human Movement, v. 24, n. 2, 2023. DOI 10.5114/hm.2023.115918. Disponível em: https://doi.org/10.5114/hm.2023.115918. Acesso em: 08 set. 2022.
Abstract: Purpose. The isometric mid-thigh pull (IMTP) test is a strength test usually requiring expensive equipment like a force platform. Low-cost alternatives could make IMTP testing more accessible. Previous research reported high systematic bias when comparing low-cost devices with more expensive criterion devices (force platforms). This study investigated the concurrent validity and intra-session reliability of a custom-built low-cost IMTP device using a load cell. Methods. Overall, 17 recreationally resistance-trained men (25 ± 6 years, 83 ± 14 kg, 178 ± 7 cm, 5 ± 3 years of resistance training experience) first visited the laboratory to be familiarized with testing protocols and returned 2–3 days later for IMTP testing with the low-cost device and a laboratory-grade force platform. Results. The overall bias was trivial (–0.8%, 95% CI: –5.7 to 4.3%). The typical error of the estimate was moderate (10.2%, 95% CI: 7.4–16.2%). A strong correlation of 0.91 (95% CI: 0.76–0.97) was found between peak force values from both devices; the low-cost IMTP device accounted for 81.3% of the variation in force platform. The low-cost IMTP also demonstrated acceptable scores for reliability and agreement (ICC = 0.96, 95% CI: 0.89–0.98; typical error = 5.0%, 95% CI: 3.7–7.7), similar to the criterion (ICC = 0.97, 95% CI: 0.91–0.99; typical error = 4.5%, 95% CI: 3.3–7.1). Conclusions. The low-cost IMTP device using a load cell was valid and reliable for maximal force production in recreationally trained men and provided results comparable with those of a force platform.
metadata.dc.description.unidade: Faculdade de Educação Física (FEF)
DOI: https://doi.org/10.5114/hm.2023.115918
Collection(s) :Artigos publicados em periódicos e afins

Affichage détaillé " class="statisticsLink btn btn-primary" href="/jspui/handle/10482/44715/statistics">



Tous les documents dans DSpace sont protégés par copyright, avec tous droits réservés.