Título : Seismic safety assessment of “Palácio do Itamaraty” at Brasília reliability-based
Autor : Rodrigues, Philipe Queiroz
Pantoja, João da Costa
Miranda, Paulo de Souza Tavares
metadata.dc.contributor.affiliation: Universidade de Brasília
Universidade de Brasília
Instituto Federal de Educação, Ciência e Tecnologia do Ceará
Assunto:: Concreto armado
Método de Hirosawa
Palácio do Itamaraty
Fecha de publicación : 2023
Editorial : Taylor & Francis
Citación : RODRIGUES, P. Q.; PANTOJA, J. C.; MIRANDA, P. S. T. Seismic safety assessment of “Palácio do Itamaraty” at Brasília reliability-based. In: INTERNATIONAL SYMPOSIUM ON LIFE-CYCLE CIVIL ENGINEERING (IALCCE 2023), 8., 2023, Milan, Italy. Proceedings [...]. London, UK: CRC Press, Taylor & Francis Group, 2023. p. 1885-1892. Disponível em: https://www.taylorfrancis.com/books/oa-edit/10.1201/9781003323020/life-cycle-structures-infrastructure-systems-fabio-biondini-dan-frangopol.
Resumen : In Brasilia (Brazil) heritage buildings have been designed without considering seismic loads. The aim of the paper is to assess seismic behavior of reinforced concrete structure of “Palácio do Itamaraty”. In this study, Monte Carlo simulation technique is implemented in Hirosawa method to examine structural level of safety. Reliability indexes for each floor are estimated and comparisons to target reliability indexes are made. The sensitivity of different input variables is also studied. Seismic indexes of structure for each floor remained greater than seismic demand indexes in all Brazilian seismic zones through Hirosawa method. Despite of, inadequate reliability indexes is noticed in all floor, which implies that structure is not enough to guarantee an adequate performance. Sensitivity analysis shows the influence of irregularity of structure in seismic response. The results highlight the importance of a probabilistic approach by Hirosawa Method to assertive decisions of conservation and rehabilitation of architectural heritage subject to seismic hazards.
metadata.dc.description.unidade: Faculdade de Arquitetura e Urbanismo (FAU)
Departamento de Tecnologia em Arquitetura e Urbanismo (FAU TEC)
metadata.dc.description.ppg: Programa de Pós-Graduação em Arquitetura e Urbanismo
Licença:: © 2023 The Author(s), ISBN 978-1-003-32302-0 Open Access: www.taylorfrancis.com, CC BY-NC-ND 4.0 license.
DOI: 10.1201/9781003323020